Lockey New Automatical Pop-up 38mm Steel Shackle Safety Padlock Lockout with Master key
Part No.: P38SPU
New Automatical Pop-up Short Steel Shackle Safety Padlock
a) Reinforced nylon body, withstand temperature from -20℃ to +80℃. The steel shackle is chrome plated; the non-conductive shackle is made from nylon, withstand temperature from -20℃ to +120℃, ensuring the strength and deformation fracture not easily.
b) Durable brass cylinder, high strength, wear-resistant, anti-rust.Testing repeatably for more than one millions times, durable in use.
c) High-end key system, KA, KD, MK, GMK available. Various key systems and quantities can be customized.
d) Pop-up design, the shackle will pop up automatically when unlocking. Press the shackle when locking, no key is needed to insert and pull out.
e) Laser printing and logo engraving available if required.
f) Different colors available.
g) Adequate stock and prompt delivery.
Part No. | Description | Shackle Material | Specification |
KA-P38SPU | Keyed Alike |
Steel |
“KA”: Each padlock is keyed the same in one group “P”: Straight edge plastic lock body “S”: Steel shackle
Other material can be customized: “SS”: Stainless steel shackle “BS”: Brass shackle |
KD-P38SPU | Keyed Differ | ||
MK-P38SPU | Keyed & Alike/Differ | ||
GMK-P38SPU | Grand Master Key | ||
KA-P38PPU | Keyed Alike |
Nylon |
|
KD-P38PPU | Keyed Differ | ||
MK-P38PPU | Keyed & Alike/Differ | ||
GMK-P38PPU | Grand Master Key |
Energy discrimination
The accident after
On May 22, 2007, the unit pressure test branch unit chief, technician, operator and other 5 people to xx to carry out pressure test work, due to the weather conditions, the unit chief secretly electrified to take a running cable, later found the time group leader has been electrocuted coma, died soon.
The cause of the accident
(I) direct causes:
The crew leader has no strong safety awareness, no supervision, no certificate on duty, illegal operation, resulting in electrocution.
(ii) indirect reasons:
Temporary power consumption is not standard, and there are problems with temporary power consumption at the construction site, which does not conform to the safety technical specification for temporary power consumption at the construction site.
The accident summary
This is a casualty accident caused by unauthorized live operation of operation personnel. It is necessary to improve the staffing of construction organizations, strengthen the study of workers' safety production rules and regulations, effectively implement HSE supervision, and strengthen construction safety management.
3. Energy discrimination and isolation
Workplace energy identification
Territorial units should identify the sources and types of all energy and materials (including utility systems) used in the operation. The energy to be controlled includes, but is not limited to, the following types:
Electrical energy: the current wing electron flow;
Kinetic energy: running equipment, etc.
Potential energy: spring, compressed gas, etc.
Chemical energy: hazardous chemicals;
Thermal energy: electric heating, cooling system.